How to use
- Under Quantity, pick illuminance, luminance, luminous intensity or luminous flux, then enter a value and units.
- The result appears large right away, and the table shows the same value in every unit.
- Lumens to candela to lux at the bottom takes a lamp’s luminous flux (lm), beam angle and distance, and returns the intensity (cd), the illuminance straight ahead (lx), and a power estimate from the luminous efficacy.
Four different quantities
The units people use for light brightness describe different things, which is why they get mixed up.
| Quantity | Typical unit | Meaning |
|---|---|---|
| Luminous flux | lumen (lm) | total light a source emits in all directions |
| Luminous intensity | candela (cd) | light strength in one direction (flux per steradian) |
| Illuminance | lux (lx) | light arriving on a surface (1 lx = 1 lm/m²) |
| Luminance | nit (cd/m²) | how bright a surface or screen looks |
What each unit is worth
| Unit | Conversion | Note |
|---|---|---|
| 1 fc (foot-candle) | 10.7639 lx | 1 lm/ft², 1 ÷ 0.09290304 |
| 1 ph (phot) | 10,000 lx | 1 lm/cm² |
| 1 sb (stilb) | 10,000 nit | 1 cd/cm² |
| 1 cd/ft² | 10.7639 nit | |
| 1 fL (foot-lambert) | 3.42626 nit | (1/π) cd/ft², used for cinema screens |
| 1 L (lambert) | 3,183.1 nit | (1/π) cd/cm² |
| 1 asb (apostilb) | 0.31831 nit | (1/π) nit |
From lumens to candela and lux
If light spreads only inside a cone of beam angle θ and is even within it, the solid angle is Ω = 2π(1 − cos(θ/2)) sr and the intensity is I = Φ ÷ Ω. For a point source, illuminance straight ahead falls with the square of distance: E = I ÷ d².
| Flux | Beam angle | Intensity | Illuminance at 2 m |
|---|---|---|---|
| 800 lm | 120° | about 254.65 cd | about 63.66 lx |
| 800 lm | 360° (all directions) | about 63.66 cd | about 15.92 lx |
Entering a luminous efficacy (lm/W) gives a rough power figure: 800 lm from a 100 lm/W source is 8 W. Efficacy varies by product, so use the number on the package or datasheet.
Worked examples
- 500 lx is about 46.45 fc, and 100 fc is about 1,076.39 lx.
- A 300 nit screen is about 87.56 fL.
- 1 fL is about 3.426 nit.
Things to keep in mind
- The calculation assumes a point source and even distribution, a simple model. Real fixtures have different beam curves, so measurements will differ.
- Required light levels for a workspace depend on the use, regulations and standards. This tool converts units and does not judge target values.
- For power and energy units see the power converter and the energy converter, and for electrical units the electrical unit converter. Other unit types are in the unit converter.
FAQ
What is the difference between lumens and lux?
Lumens are the total light a source emits, and lux is how bright that light is on a surface. The same 800 lm bulb gives fewer lux on a distant desk and more if the light is focused.
Can I convert lumens to candela?
Yes, if you know the beam angle. A bulb that spreads evenly in all directions gives candela = lumens ÷ 4π (about 12.57), and a narrower beam gives more candela for the same lumens. There is no formula without the beam angle.
How many lux is 1 foot-candle?
About 10.7639 lx, since one foot-candle is one lumen per square foot and a square foot is 0.09290304 m². Multiplying by 10 is a fair rough guide.
Are nits and candela the same thing?
1 nit is 1 cd/m², the same quantity under another name. The candela is the unit of intensity, and dividing by area gives luminance, the nit.
Are my values sent to a server?
No. Values you enter are processed only in your browser and never sent to a server.