How to use
- Drop or choose your
.dcmfiles. You can pick all the files of a series at once. DICOM files from a hospital CD often have no extension; those open too. - Drag on the image to change brightness and contrast (the window). Dragging sideways changes the window width, up and down changes the window center. CT images get lung, brain, bone and abdomen presets.
- Use the wheel or the slider to move between slices, and Ctrl + wheel or the zoom buttons to change size. Switch to “Pan” to move the image, or “Measure” to measure between two points.
- Read the study, series and equipment tags under Information. Save as PNG saves the image with the brightness you see.
Supported formats
| Transfer syntax | Result |
|---|---|
| Implicit VR Little Endian, Explicit VR Little Endian | Opens (uncompressed) |
| RLE Lossless | Opens (decoded directly) |
| JPEG Baseline (8-bit) | Opens (browser decoder) |
| JPEG Lossless, JPEG-LS, JPEG 2000, 12-bit JPEG | Does not open; the reason is shown |
| Explicit VR Big Endian, Deflated | Does not open |
Grayscale (MONOCHROME1 and 2) and RGB images with 8 or 16 bits are supported. A multi-frame file is browsed one frame per slice.
Brightness and the window
A CT image’s stored values become HU (Hounsfield units) through Rescale Slope and Intercept. For example, a stored value of 1064 with intercept -1024 and slope 1 is 40 HU. The display spreads only a range of those values over black to white, centered on the window center and as wide as the window width. A narrow window gives high contrast; a wide one shows a broad range.
| Preset | Center | Width |
|---|---|---|
| Lung | -600 | 1500 |
| Brain | 40 | 80 |
| Bone | 400 | 1800 |
| Abdomen | 40 | 400 |
The first window comes from the file’s Window Center and Width tags; without them the full range of the image is used. MONOCHROME1 stores bright values as dark, so it is inverted from the start. The formula is the linear function from the DICOM standard (PS3.3 C.11.2.1.2).
Series and distance
- Several files are grouped by Series Instance UID. Inside a series they are sorted by Instance Number, then Slice Location, then the order you selected them.
- Distances are shown in mm when Pixel Spacing (row and column spacing) is present, otherwise in pixels.
Privacy and PNG export
- Patient name, ID, birth date, address, phone number, accession number and institution name are hidden by default. Turn on “Show patient identifiers” to see them.
- A PNG contains image pixels only, with no DICOM tags, and its file name is just a number such as
dicom-image-001.png. - Text burned into the image itself (common in ultrasound and X-ray) cannot be hidden, so check before sharing.
What it cannot do
- Diagnosis or reading. This tool is not for diagnostic use. Medical decisions belong to cleared medical software and a physician.
- 3D reconstruction, MPR, volume measurement, or connecting to a PACS server
- The compressed formats marked “does not open” above, and palette color